NVIDIA/Mellanox MMS4A00-XM (980-9IAH1-00XM00) Compatible 1.6T 2xDR4/DR8 OSFP224 IHS/Closed Finned Top PAM4 Broadcom 3nm DSP (Sian3 | BCM83628) 1310nm 500m SMF DOM Dual MPO-12/APC InfiniBand XDR Silicon Photonics Transceiver Module for Quantum-X800 Air-Cooled Switches

#102514
Model: OSFP-1.6T-2xDR4H
Sold: 60k+
In Production: 2.5k | Delivery from Jan. 2026
$
Brand:
NADDOD (InfiniBand)
NADDOD (InfiniBand)
Chip Solutions:
Broadcom Sian3 | BCM83628
Broadcom Sian3 | BCM83628

Item Spotlights

  • Built-in Broadcom 3nm DSP (Sian3 BCM83628) and self-developed silicon photonics chip.
  • Fully validated for interoperability with NVIDIA Quantum-X800 air-cooled switches.
  • Compatible with DGX B300, GB300 server architectures.
  • Supporting 1.6T to 2x800G NIC Connectivity.
  • Maximum power consumption ≤25W.
  • 8x200G-PAM4 electrical modulation.
  • Compliant with OSFP MSA, IEEE 802.3dj_D1.1 protocol and CMIS 5.2.
  • 30-Day Free Return, 1-Year Free Replacement, 3-Year Warranty, Lifetime After-sales Technical Support.
1.6T 2xDR4/DR8 OSFP224 MMS4A00-XM PAM4 1310nm 500m InfiniBand XDR Silicon Photonics Transceiver for Mellanox(SMF, Closed Finned Top)
NVIDIA/Mellanox MMS4A00-XM (980-9IAH1-00XM00) Compatible 1.6T 2xDR4/DR8 OSFP224 IHS/Closed Finned Top PAM4 Broadcom 3nm DSP (Sian3 | BCM83628) 1310nm 500m SMF DOM Dual MPO-12/APC InfiniBand XDR Silicon Photonics Transceiver Module for Quantum-X800 Air-Cooled Switches
Specifications
Applications
Product Highlights
Videos
Questions & Answers
Resources
Specifications
Applications
Product Highlights
Videos
Questions & Answers
Resources

Description

NVIDIA/Mellanox MMS4A00-XM (980-9IAH1-00XM00) Compatible 1.6T 2xDR4/DR8 InfiniBand XDR Silicon Photonics Optical Transceiver Module (Twin-port OSFP224, Broadcom 3nm DSP | Sian3 BCM83628, 1310nm, 500m (OS2) , Dual MPO-12/APC, DOM, SMF, IHS/Closed Finned Top)

NADDOD OSFP-1.6T-2xDR4H Optical Transceiver is an InfiniBand and Ethernet 1.6Tb/s 2x800Gb/s Twin-port OSFP224, 2xDR4/DR8 single mode, Silicon photonics-based, parallel, 8-channel transceiver using two, 4-channel MPO-12/APC optical connectors at 800Gb/s each. The parallel single mode, data center reach 8-channel (2xDR4/DR8) design uses 200G-PAM4 modulation and has a maximum fiberreach of 500-meters using 8 single mode fibers. The main application for OSFP-1.6T-2xDR4H is linking two switches together with up to 500 meters.

Specifications

Form Factor
OSFP224
Distance
500m
Wavelength
1310nm
Connector
Dual MPO-12 /APC
Power Consumption
≤25W
Transmitter
DFB (SiPh Based)
Receiver
PIN (SiPh Based)
Media
SMF
Modulation (Electrical)
8x212Gb/s PAM4
Modulation (Optical)
Two ports 4x212Gb/s PAM4
Case Temperature (℃)
0~70°C (32 to 158°F)
Protocol
IB XDR, 1.6T Ethernet Compliant

Applications

Product Highlights

Broadcom 3nm DSP & NADDOD SiPh: Setting a New Benchmark for Next-Gen XDR Network

Leveraging the synergy between Broadcom's 3nm DSP and self-developed silicon photonics chip, the 1.6T transceiver is designed for XDR networks. Tested with the NVIDIA Quantum-X800 Q3400-RA switch, it delivers low power consumption of 25W, a BER of 5E-14, and seamless compatibility with ConnectX-8 NICs (C8180/C8280U). Supporting CX8-equipped servers such as DGX GB300/B300 and HGX B200 for high-speed interconnects, it scales from small-to-medium AI inference/training nodes to large AI factory-class clusters, setting a new performance benchmark for 1.6T XDR interconnects.

Cluster-Scale Energy Efficiency Leap: Accelerating AI Training

NADDOD’s XDR solution featuring the 1.6T transceiver boosts cluster energy efficiency through high bandwidth density and an optimized link architecture. In a 512-node AI cluster, this solution cuts ~ 7 racks (assuming a 20kW, 42U rack configuration) compared to NDR solution, saving 130.4kW (≈ 16–26 GPU servers’ power). Overall, it reduces data center operational costs, simplifies cabling, enhances space utilization, and enables flexible scaling—delivering efficient, sustainable connectivity for next-gen AI data centers.

3nm Stable Supply & Multi-Route Chip R&D: Ensuring Reliable 1.6T Transceivers with Scalability

Amid the global XDR chip shortage, NADDOD leverages Broadcom's stable supply of 3nm DSPs to reliably deliver 1.6T transceivers in bulk. We also strengthen chip R&D: Our self-developed silicon photonics (validated for key performance) enables easy mass production thanks to its high level of integration, providing customers with more competitive costs and reliable delivery. Meanwhile, we deploy the EML technology route, offering greater flexibility in chip selection to support product iteration and large-scale deployment for 1.6T/3.2T and future AIDC scenarios.

Server-Class Interconnects: Unlock Cluster Performance

The 1.6T transceiver is compatible with DGX GB300, B200, HGX, and other mainstream high-density GPU servers, fully releasing the computing power of each GPU node and comprehensively boosting overall cluster performance. Ideal for AI, HPC, and large-scale inference tasks, it features high-speed, low-latency links that ensure seamless communication—activating maximum cluster throughput and resource utilization to deliver an efficient, reliable, and scalable computing infrastructure solution for customers.

Why NADDOD

  • Module Availability
    Worry-Free - Rigorous authentic testing!
  • Multi-version Device Compatibility
    Multi-Version - Easy adaptation for each module!
  • High-Performance
    Actual Test Data-Better results intuitively!

Our Approach

Test scene
Test scene
NADDOD stringently selects a series of items in a professional testing environment to ensure the perfect blend of product performance and reliability. Including hardware compatibility (plugging, unplugging, rebooting), software compatibility (connectivity, parameters) and performance testing (DDM, BER, stability).
Test result
NVIDIA Quantum-X800 Q3400-RA XDR Switch
Software version: 25.02.5002
  • Multi-Version
    Switch Side Testing
    Multi-Version  Testing
    No matter the device version, the optical modules are rigorously tested to ensure seamless integration with various hardware and software versions.
  • Connectivity
    Switch Side Testing
    Connectivity  Testing
    The module can connect to both devices normally, and the device port status is up.
  • BER
    Switch Side Testing
    BER  Testing
    Tests REAL-TIME BER to ensure the accuracy of data transmission under high load conditions.
Test result
Test result
Test result

Questions & Answers

Ask a Question
Q:
What are the practical differences of 3nm DSP over common 5nm DSP solutions in real use?
A:
NADDOD's 1.6T transceiver features Broadcom's 3nm DSP (BCM83628). It boasts lower power consumption and better overall performance than 5nm DSP solutions, while significantly lowering the port failure rate and further enhancing link stability in actual deployment. Tested on the NVIDIA Quantum-X800 Q3400 switch, the 3nm solution delivers higher energy efficiency and stability, ensuring efficient and reliable operation of large AI clusters.
Q:
When should I choose XDR networking instead of NDR networking?
A:
For AI clusters with 512 to 1024 nodes, XDR networking is the best choice. At this scale, XDR networking delivers higher cost-efficiency and network reliability. For example, the total cost can be reduced by 41% compared with NDR networking in a 512-node deployment scenario. Compared with NDR networking, it requires fewer switches and transceivers, thus reducing rack space, power consumption, simplifying cabling, and lowering O&M costs.
Q:
I am using NVIDIA DGX B300 or DGX GB300 servers now, can this XDR transceiver be directly deployed?
A:
Yes, it is fully compatible for direct use. This XDR transceiver supports interconnection between switches and NVIDIA DGX B300/DGX GB300 servers equipped with ConnectX-8 network cards. It can be directly deployed in existing clusters without additional adaptation or special configuration.
View More

Quality Certification

ISO140012015
ISO 90012015
ISO450012018
FDA
FCC
CE
RoHS
TUV-Mark
UL
WEEE

What We Supply